Your browser does not support this function, please mannually add this page to your favorites ( Ctrl + D)

Connection hose for 3-way catalytic converter cleaner

Cleaner for three-way catalytic converter
SYSCLNR-VEH-LIGHTYELLOW-350ML

Art.-no. 5861112160
EAN 4056807788005

Prices for customers after login
Connection hose for 3-way catalytic converter cleaner

Art.-no. 5861112160

Prices for customers after login
Quantity
PU

Exclusively for trade customers

Register now and access more than 125,000 products

Used to connect the intake manifold vacuum tube, remove the surface covering of the catalyst and oxygen sensor, and restore the catalyst and extend the service life.

Effectively reduce the emission of harmful gases such as HC, CO, and NOX.



Restore the original power level of the car, reduce fuel consumption.



Simultaneously clean the engine combustion chamber, intake valve and other parts of carbon deposits.

Product information

Datasheets(X)

Safety data sheet

Certificates/ Documents

 | 

 | 

Application area
  • Remove a vacuum from the intake manifold without the engine starting tube, preferably from the carbon tank solenoid valve to the intake manifold vacuum tube.

  • Connect the nozzle of the cleaning equipment with the vacuum tube and close it

  • Close the flow control valve of the cleaning device.

  • Start engine, displacement 2.0L and above vehicles to keep idle state, exhaust

  • For vehicles under 2.0L, keep the engine speed at 1500 r/min. Then slow down slowly open the flow control valve of the cleaning equipment, so that the cleaning agent atomized into the hair Motivation burns.

  • The control of detergent flow rate is light when the engine is running at idle speed . If the engine shakes seriously during the cleaning process, to reduce the cleaning agent flow to the normal operation of the engine.

  • During the cleaning process, do not accelerate, always pay attention to the flow of cleaning agent.

  • After cleaning, let the engine idle to continue running for 2-3 minutes, and then reverse step up the throttle and clean the surface of oxygen sensor and ternary catalytic converter the dropped attachments are discharged until the exhaust pipe is free of grayish black or cyan smoke discharge.

  • Because irritating gas will be produced during the cleaning process, it is recommended to be ventilated in open space to work.
InstructionsA three-way catalytic converter cannot be cleaned under the following circumstances:
  • a) The engine is not working normally, there is shaking, abnormal noise, serious burning oil, bright obvious lack of cylinder or fire break;

  • b) the ternary catalytic converter has been sintered or damaged;

  • c) Three-way catalytic converters that do not meet the quality requirements of automobile manufacturers.

Contents

350 ml

Colour

Light yellow

Smell/fragrance

Solvent-like

Chemical basis

Alcohol with additives

Shelf life from production

24 Month

Density

0.68 g/cm³

Density conditions

at 23°C, 50% relative humidity

Min. flashing point

15.2 °C

Additive article:
 
Product
Description
Quantity
PU
Untaxed price
/PU
Connection hose

CONHOSE-(F.SYSCLNR-VEH-CATLYCLNR)

x 1 pcs
The packaging unit defines the number of articles in one packaging. In the catalog segment you can choose from different packaging units if a pop-up menu is displayed.

Just leave the field empty if you don't know the packaging unit when directly entering the article number in the shopping basket or when importing with Easy-/VarioScan. The packaging unit will be determined automatically.
The article number is made up of the following: VVVVAAABBB
VVVV = 4 digits for prefix number (please note that the first digit is currently always 0)
AAA = 3 digits for dimension part 1
BBB = 3 digits for dimension part 2

Example article number structures:
Example 1: Screw with dimensions of 4x10 mm:
VVVVAAABBB
00574 10 (2 spaces between the 4 and the 10)

Example 2: Screw with dimensions of 10x20 mm:
VVVVAAABBB
005710 20 (1 space between the 10 and the 20)

Example 3: Flat washer with an internal diameter of 6 mm:
VVVVAAABBB
04076
Price per packaging unit (PU):
The displayed price is always in line with the displayed packaging, if the PU is 250 the price for 250 units, if the PU is 300 the price for 300 units.

Price with price key representation (PSL):
The price always applies to a quantity ruled through the price key:
Price for 1 unit
Price for 100 units
Price for 1000 units
The quantity shows the number of pieces or units of measure contained in the order or delivery for the respective article.
In contrast to sales packaging and secondary packaging, the disposal costs for chemical-technical products are shown separately. The breakdown of the individual costs can be found on the relevant products and also in the shopping cart, as well as in our General Terms and Conditions (GTC).

Art.-no.
Cust. Mat. No.

Hazardous Material

Product information

Datasheets()

Datasheets ()

CAD data  | 

Certificates/ Documents

 | 

 | 

Technical information